During the wrecking of any building or during other construction operations, where
deemed necessary, the director of buildings and inspections may require outrigger
scaffolds to be constructed on all sides of the building which are within ten feet
of a traveled thoroughfare and on all sides that are adjacent to and extend above
any occupied building lot. These outrigger scaffolds shall be located not more than
two stories below the point where any wrecking or handling of outside wall material
is being done. The floor, or platform, of all such outrigger scaffolds shall be tightly
laid from the edge of the building and shall be at least eight feet wide with a 42
inch solid railing or footboard at the outside edge. The flooring and its support,
or outriggers, shall be capable of sustaining a live load of not less than 125 pounds
per square foot.
(Ordained by Ord. No. 67-1996, eff. Apr. 5, 1996)